CT Soft Tissue Neck

8/31/2017

Helical 3.75mm x 3.75mm Standard Algorithm

Recon 2: 2.5mm x 2.5mm Standard Algorithm

Recon 3: 0.625mm spacing x 1.25mm thickness Standard Algorithm

Recon 4: 2.5mm x 2.5mm Bone Algorithm

Sag/Cor 2mm x 2mm Reformats from Recon 3

Send recon 2, Recon 4 and Sag/Cor reformats to PACS

TIMING DELAYS FOR CT NECK

DELAY PROGRAMMED ON THE SCANNER: 115 SECONDS

START SCANNER AND INJECTOR SIMULTANEOUSLY.

PROGRAM INJECTOR WITH TWO SEPARATE INJECTIONS (70 ml and 30 ml) WITH A 75 SECOND DELAY BETWEEN INJECTIONS.

INJECTION AMOUNT AND RATE FOR FIRST INJECTION:

70 ml CONTRAST @ 2.5 ml PER SECOND

INJECTION AMOUNT AND RATE FOR SECOND INJECTION:

30 ml CONTRAST @ 2.5 ml PER SECOND

AFTER SECOND INJECTION, TELL PT NOT TO BREATHE OR SWALLOW

SCAN NECK AS PER EXISTING PROTOCOL

THIS TIMING PROTOCOL IS TO REPLACE THE OLD 40 SECOND DELAY THAT WAS IN PLACE PREVIOUSLY.